2024.3.18
|
Fukushima Daiichi Nuclear Power Station Unit 1 Primary Containment Vessel Internal Investigation (Non-Submerged Area) Status Inside the Pedestal
|
2022.4.13
|
Commencement of installation of large cover in preparation for the removal of spent fuel from Fukushima Daiichi Nuclear Power Station Unit 1 (Anchor drilling)
|
2022.3.24
|
Implementation Status of Unit 1 Primary Containment Vessel Internal Investigation (ROV-A2) (work conducted between March 14~16) at the Fukushima Daiichi Nuclear Power Station
|
2022.2.10
|
Implementation Status of the Unit 1 Primary Containment Vessel Internal Investigation (As of February 10) at the Fukushima Daiichi Nuclear Power Station
|
2022.2.9
|
Implementation Status of the Unit 1 Primary Containment Vessel Internal Investigation (As of February 9) at the Fukushima Daiichi Nuclear Power Station
|
2020.6.11
|
Completion of air mortar injection into the Fukushima Daiichi Nuclear Power Station Unit 1 SFP cover bag
|
2017.4.7
|
Unit 1 Primary Containment Vessel Internal Investigation(deposition sample collection)
|
2017.4.3
|
Unit 1 Primary Containment Vessel internal investigation (State of the field work)
|
2017.3.27
|
Unit 1 Primary Containment Vessel Internal Investigation
|
2017.3.23
|
Progress of Unit 1 PCV internal investigation (Preliminary report of March 22 investigation)
|
2017.3.22
|
Progress of Unit 1 PCV internal investigation (Preliminary report of March 21 investigation)
|
2017.3.21
|
Progress of Unit 1 PCV internal investigation (Preliminary report of March 19 and 20 investigations)
|
2017.3.19
|
Progress of Unit 1 PCV internal investigation (Preliminary report of March 18 investigation)
|
2017.3.18
|
Progress of Unit 1 PCV internal investigation (Beginning of the investigation)
|
2016.11.10
|
Removal of all wall panels (18 in total) from the Unit 1 reactor building cover completed at Fukushima Daiichi Nuclear Power Station
|
2016.10.7
|
Removal of the 8th wall panel over Unit 1 reactor building at Fukushima Daiichi Nuclear Power Station
|
2016.9.26
|
Radiation Dose Survey for the Units 1-2 Exhaust Stack at Fukushima Daiichi Nuclear Power Station
|
2016.9.13
|
First Wall Panel Removal from Unit 1 Building Cover at Fukushima Daiichi Nuclear Power Station
|
2016.4.6
|
Start of Nozzle Unit Installations for Mist Sprinkler Associated with the Dismantling of Unit 1 Reactor Building Cover
|
2015.11.18
|
Training to Remove Obstacled Steel Frames Using the Mock-up Facility for Unit 1 Reactor Building of the Fukushima Daiichi Nuclear Power Station
|
2015.10.6
|
Completion of Roof Panel Removal from Unit 1 Building Cover at Fukushima Daiichi Nuclear Power Station
|
2015.7.28
|
Removing roof panels of Unit 1 reactor building cover at Fukushima Daiichi Nuclear Power Station (the 1st panel)
|
2015.5.22
|
The Balloon Sliding Off the 3rd Floor Equipment Hatch inside Unit 1 Reactor Building at Fukushima Daiichi Nuclear Power Station
|
2015.5.15
|
Start Dismantling Unit 1 Reactor Building Cover <Start Sprinkling Anti-scattering Agent>
|
2015.4.20
|
"Development of a technology to investigate inside the Reactor Primary Containment Vessel (PCV)"- Results of follow up check after the site test "Investigation B1"on grating around the pedestal inside Unit 1 PCV - [Report for April 18 and April 19, 2015]
|
2015.4.17
|
(4/20 video added) "Development of a technology to investigate inside the Reactor Primary Containment Vessel (PCV)" - Site test "Investigation B1" on grating around the pedestal inside Unit 1 PCV - [Prompt report for April 16, 2015]
|
2015.4.16
|
(4/17 video added) "Development of a technology to investigate inside the Reactor Primary Containment Vessel (PCV)" - Site test "Investigation B1" on grating around the pedestal inside Unit 1 PCV -[Prompt report for April 15]
|
2015.4.13
|
"Development of a technology to investigate inside the Reactor Primary Containment Vessel (PCV)" -Site test "Investigation B1" report on grating around the pedestal inside Unit 1 PCV-
|
2015.4.10
|
"Development of a technology to investigate inside the Reactor Primary Containment Vessel (PCV)"‐Site test "Investigation B1" report on grating around the pedestal inside Unit 1 PCV‐(Prompt report of inspection commencement on April 10, 2015)
|
2015.3.19
|
Reactor Imaging Technology for Fuel Debris Detection by Cosmic Ray Muon, Measurement Status Report in Unit-1
|
2015.2.22
|
[Technical Committee on Nuclear Power Safety Management in Niigata Prefecture] Explanation on the 4th floor investigation of the Unit 1 reactor building at Fukushima Daiichi NPS
|
2015.2.9
|
Development for fuel debris detection technology for reactor at Fukushima Daiichi Nuclear Power Station (Unit 1)
|
2014.12.20
|
Spraying Anti-scattering Agents and Survey Result for Unit 1 Building Cover Demolition
|
2014.12.4
|
Restoring roof panels for the demolition of Unit 1 reactor building cover at Fukushima Daiichi NPS
|
2014.11.10
|
Removing the roof panels of Unit 1 reactor building cover (the 2nd panel)
|
2014.10.31
|
Removing the roof panels of Unit 1 reactor building cover (the south 3 roof panel)
|
2014.10.28
|
Enlarged Opening on the Roof Panels at the Demolition Work of Unit 1 Reactor Building Cover
|
2014.10.22
|
Dismantling of Unit 1 reactor building cover
|
2014.5.30
|
Demonstration test of survey equipment for the upper part of S/C (Pressure Suppression Chamber) at Unit 1 of the Fukushima Daiichi Nuclear Power Station.
|
2014.5.27
|
Results of Investigation on Upper Parts of S/C of Unit 1 at Fukushima Daiichi NPS
|
2014.2.7
|
Verification test of decontamination device for lower place under a national project of "Development of Remote Decontamination Technology in the Reactor Building" (Suction/blast device)
|
2013.12.6
|
Measuring Radiation Dose at the Lower Part of Unit 1 and 2 Exhaust Stack in Fukushima Daiichi NPS
|
2013.12.6
|
(A video was added on December 13)Results of Investigation into Building Frames around Unit 1 Reactor Building Equipment Hatch at Fukushima Daiichi NPS
|
2013.11.14
|
Results of Investigation around Lower Parts of Unit 1 Vent Pipes at Fukushima Daiichi NPS(Second Day)
|
2013.11.13
|
(A video was added on November 15) Results of Investigation around Lower Parts of Unit 1 Vent Pipes at Fukushima Daiichi NPS(First Day)
|
2013.9.18
|
Fracture Found on Steel Members (Diagonal Bracings) in the Intermediate Section of the Exhaust Stack for Units 1 and 2 at Fukushima Daiichi NPS
|
2013.9.18
|
Investigation into Building Frames around at Unit 1 Reactor Building Equipment Hatch at Fukushima Daiichi NPS
|
2013.9.4
|
Investigation Results of Groundwater Inflow at Unit 1 Turbine Building and the Miscellaneous Solid Waste Volume Reduction Treatment Building (High Temperature Incinerator Building) in Fukushima Daiichi Nuclear Power Station
|
2013.5.9
|
Dismantlement of Unit 1 Reactor Building Cover for Fuel Removal at Fukushima Daiichi Nuclear Power Station
|
2013.4.9
|
Results of Investigation of the Personnel Access Lock Room on the First Floor of Unit 1 Reactor Building at Fukushima Daiichi Nuclear Power Station
|
2013.3.28
|
The fourth floor of Unit 1 Reactor Building at Fukushima Daiichi Nuclear Power Station (March 28, 2013)
|
2013.2.22
|
Investigation of Unit 1 Torus Room at Fukushima Daiichi Nuclear Power Station (Day 2)
|
2013.2.21
|
Investigation of Unit 1 Torus Room at Fukushima Daiichi Nuclear Power Station (Day 1)
|
2013.2.15
|
Investigation of the fourth floor of Unit 1 Reactor Building at Fukushima Daiichi Nuclear Power Station(Video on Nov 30, 2012)
|
2013.2.14
|
Drilling Holes for the Investigation of Unit 1 Torus Room at Fukushima Daiichi Nuclear Power Station
|
2013.2.7
|
Video of the inside of the Unit 1 Reactor Building at Fukushima Daiichi Nuclear Power Station shown to the investigative panel appointed by the parliament on February 28, 2012 (Videotaped on October 18, 2011)
|
2013.2.1
|
Photos of the Accident at Fukushima Daiichi Nuclear Power Station (Publicized on February 1, 2013)
|
2012.12.3
|
National Academy of Science USA Visiting Fukushima Daiichi Nuclear Power Station
|
2012.10.24
|
Results of Reinvestigation of Unit 1 Operation Floor at Fukushima Daiichi Nuclear Power Station
|
2012.10.19
|
Fire Occurred Near Units 1-2 Ultrahigh Voltage Switchyard (Outdoor) at Fukushima Daiichi Nuclear Power Station
|
2012.10.15
|
Investigation of the Inside of Unit 1 PCV at Fukushima Daiichi Nuclear Power Station (October 12,13)
|
2012.10.12
|
Investigation of inside of the PCV of Unit 1, Fukushima Daiichi NPP
|
2012.10.11
|
Investigation of inside of the PCV of Unit 1, Fukushima Daiichi NPP
|
2012.10.10
|
Investigation of inside of the PCV of Unit 1, Fukushima Daiichi NPP
|
2012.9.27
|
Punching an Access Hole at the Penetration of Unit 1 PCV at Fukushima Daiichi Nuclear Power Station
|
2012.9.11
|
(39)Unit 1 and 2 Ultraigh Voltage Switchyard Area (Inside)
|
2012.9.11
|
(38)Unit 1 and 2 Ultraigh Voltage Switchyard Area (Outside)
|
2012.9.11
|
(36)Unit 1 Transformer Area
|
2012.9.11
|
(34)Around the Unit 1 Large Equipment Hatch
|
2012.9.11
|
(29)Sea side area of Unit 1
|
2012.9.11
|
(24)Inside the Unit 1 Power Source Room
|
2012.9.11
|
(15)The Situation at Fukushima Daiichi Nuclear Power Station after the explosion of Unit 1,3 and 4.
|
2012.9.11
|
(7)Appearance of Unit 1 after the explosion
|
2012.9.11
|
Decrease in the Reactor Injection Amounts at Unit 1-3 at Fukushima Daiichi Nuclear Power Station (Follow-up Report)
|
2012.8.8
|
Result of Investigation on Unit 1 Operating Floor at Fukushima Daiichi Nuclear Power Station
|
2012.7.5
|
Investigation Result of Unit 1 Reactor Building TIP Room and South Area at Fukushima Daiichi Nuclear Power Station
|
2012.6.27
|
Fukushima Daiichi Nuclear Power Station Unit 1 Reactor Building Torus Room Investigation Result (June 26, 2012)
|
2012.5.25
|
【Video】"Development of Remote Decontamination Technology in the Reactor Building" Robot Investigation Results of Unit 1 Reactor Building
|
2012.3.2
|
Result of Visual Inspection of Inside of Primary Containment Vessels at Fukushima Daini Nuclear Power Station
|
2012.2.24
|
TEPCO's explanatory material for the workshop of technique catalogue related to equipment/device development for preparation of fuel debris removal towards the decommissioning of Fukushima Daiichi Nuclear Power Station
|
2012.1.26
|
Response training to abnormal conditions that occurred at Spent Fuel Pool per the Safety Regulation
|
2012.1.20
|
Current Status of Fukushima Daiichi Nuclear Power Station by photographs
|
2012.1.16
|
Scenery of obstacle removal by crane barge at intake cannel of Unit 1 to 4
|
2011.12.17
|
Current view of Fukushima Daiichi Nuclear Power Plant
|
2011.11.30
|
Establishment of New Routes for Nitrogen Injection into RPV at Units 1-3 of Fukushima Daiichi Nuclear Power Station
|
2011.11.2
|
Overview of the blocking operation of the units 1 - 4 openings
|
2011.10.28
|
Ancillary facilities for cover panels of Unit 1(Completion of Cover Construction at Reactor Building of Unit 1 of Fukushima Daiichi NPS)
|
2011.10.21
|
Isolation Condenser of Unit 1, Fukushima Daiichi Nuclaer Power Station
|
2011.10.15
|
Result of temperature measurement by infrared camera from right above the reactor
|
2011.10.14
|
Survey results of pipe penetration on 1st floor of Unit 1 reactor building
|
2011.10.14
|
Completion of installing the roof panel of the cover for the reactor building at Unit 1
|
2011.10.11
|
Overview of dust sampling at the openings of Unit 1 Reactor Building in Fukushima Daiichi Nuclear Power Station
|
2011.10.10
|
1st floor of Reactor Building, Unit 1, Fukushima Daiichi Nuclear Power Station Cutoff operation for a spray system pipe of RPV
|
2011.10.10
|
1st floor of Reactor Building, Unit 1, Fukushima Daiichi Nuclear Power Station Cutoff operation for a spray system pipe of RPV
|
2011.10.8
|
Situation of Upper Part of Unit 1 Reactor Building, Fukushima Daiichi Nuclear Power Station
|
2011.10.8
|
Status of Fukushima Daiichi Nuclear Power Plants shown in photos
|
2011.10.8
|
Installation Work of Roof Panels for Reactor Building Covers at Unit 1 of Fukushima Daiichi Nuclear Power Plant
|
2011.9.17
|
Fukushima Daiichi Nuclear Power Plant Photo Collection
|
2011.9.12
|
A view of dust sampling at the upper part of the Reactor Building of Unit 1 at Fukushima Daiichi Nuclear Power Station
|
2011.9.10
|
Fukushima Daiichi Nuclear Power Station Dust sampling instrument for opening of Units 1 and 3 nuclear reactor buildings
|
2011.9.10
|
Unit 1, Fukushima Daiichi NPS, Construction of steel erection for cover of reactor building completed
|
2011.9.9
|
Current situation of outdoor water exposure Fukushima Daiichi Nuclear Power Station
|
2011.8.30
|
Dust-sampling Opening of Reactor Building of Unit 1and 2, Fukushima Daiichi Nuclear Power Station
|
2011.8.10
|
Status of iron frame construction for the reactor building cover of Unit 1 at Fukushima Daiichi Nuclear Power Station
|
2011.8.5
|
Stack drain pipe of exhaust stack of Units 1 and 2
|
2011.8.3
|
Place where high radiation dose was detected, Unit1, at Fukushima Daiichi Nuclear Power Station
|
2011.8.2
|
Main Exhaust Stuck of Unit 1/2
|
2011.7.29
|
Rest area on the 2nd floor of Unit1/2 Service Building
|
2011.7.29
|
Rest area for construction of covers of Unit1 Reactor Building(Shimizu Corporation)
|
2011.7.26
|
Installation of reactor building cover Unit 1, Fukushima Daiichi Nuclear Power Station
|
2011.7.7
|
Trial fitting of the cover for Unit 1, Fukushima Daiichi Nuclear Power Station at Onahama port
|
2011.6.23
|
Picture regarding sampling of radioactive materials in the air above reactor building of Fukushima Daiichi Nuclear Power Station Unit 1
|
2011.6.14
|
Outline of Fukushima Daiichi Nuclear Power Plant unit1reactor building covering plan
|
2011.6.4
|
Fukushima Daiichi Nuclear Power Station Temporary reactor pressure indicators
|
2011.6.4
|
Confirmation of steam situation at a reactor building of Fukushima Daiichi Nuclear Power Plant Unit 1
|
2011.5.28
|
Spraying dust inhibitor at Fukushima Daiichi Nuclear Power Station
|
2011.5.24
|
Picture regarding sampling of radioactive materials in the air above reactor building of Fukushima Daiichi Nuclear Power Station
|
2011.5.17
|
Fukushima Daiichi Nuclear Power Station Current status of restoration work
|
2011.5.12
|
Inspection Status of the Indicator (Water level indicator A, fuel area) at Unit 1, Fukushima Daiichi Nuclear Power Station
|
2011.5.9
|
North side of the second floor ,Northwest side of the first floor(Fukushima Daiichi Nuclear Power Station Unit1)
|
2011.5.8
|
Fukushima Daiichi Nuclear Power Station Status of Improved Working Environment Inside of Reactor Building of Unit 1-First Floor of Turbine Building of Unit 1
|
2011.5.6
|
Inside the reactor building of Fukushima Daiichi Nuclear Power Station Unit 1
|
2011.5.5
|
The ambient air filtration system (Alara Venti Jumbo)
|
2011.5.3
|
Site observation by the packbot in the nuclear reactor building of Unit 1
|
2011.4.29
|
Site observation by the packbot in the nuclear reactor building of Unit 1
|
2011.4.27
|
Movies taken from T-Hawk
|
2011.4.27
|
Site observation by the packbot in the nuclear reactor building of Unit 1
|
2011.4.20
|
The photos were taken by the Packbot inside the nuclear reactor building of Fukushima Daiichi Nuclear Power Station(video)
|
2011.4.19
|
The photos were taken by the Packbot inside the nuclear reactor building of Fukushima Daiichi Nuclear Power Station(picture)
|
2011.4.16
|
Movies taken from T-Hawk, Reactor Building, Unit 1, 3,4 Fukushima Daiichi Nuclear Power Station
|
2011.4.15
|
A picture taken from T-Hawk, Reactor Building, Unit 1, Fukushima Daiichi Nuclear Power Station
|
2011.4.12
|
Fukushima Daiichi Nuclear Power Station(When fire was detected, After initial extinction, Before installing steel water bars, Sampling of water from the spent fuel pool)
|
2011.4.11
|
Motion pictures of Fukushima Daiichi Nuclear Power Station
|
2011.3.24
|
Control room for Unit 1 of Fukushima Daiichi Nuclear Power Station
|
2011.3.16
|
Unit 1 - 4 of Fukushima Daiichi Nuclear Power Station
|
2011.3.11
|
Unit 1 of Fukushima Daiichi Nuclear Power Station
|